You're $50 Away from Free Shipping!
ATC SLA-230-ASA Voltage Monitoring Relay | 190-270V Adjustable Operating Range | Screwdriver Adjustment | Octal Plug-in with Dust Cover | Ideal for Industrial Control Panels & Power Distribution Systems
ATC SLA-230-ASA Voltage Monitoring Relay | 190-270V Adjustable Operating Range | Screwdriver Adjustment | Octal Plug-in with Dust Cover | Ideal for Industrial Control Panels & Power Distribution SystemsATC SLA-230-ASA Voltage Monitoring Relay | 190-270V Adjustable Operating Range | Screwdriver Adjustment | Octal Plug-in with Dust Cover | Ideal for Industrial Control Panels & Power Distribution SystemsATC SLA-230-ASA Voltage Monitoring Relay | 190-270V Adjustable Operating Range | Screwdriver Adjustment | Octal Plug-in with Dust Cover | Ideal for Industrial Control Panels & Power Distribution SystemsATC SLA-230-ASA Voltage Monitoring Relay | 190-270V Adjustable Operating Range | Screwdriver Adjustment | Octal Plug-in with Dust Cover | Ideal for Industrial Control Panels & Power Distribution Systems

ATC SLA-230-ASA Voltage Monitoring Relay | 190-270V Adjustable Operating Range | Screwdriver Adjustment | Octal Plug-in with Dust Cover | Ideal for Industrial Control Panels & Power Distribution Systems

$77.87 $141.59 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:13 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:45607927

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

The ATC Diversified SLA Series is designed to protect 3-phase equipment against Phase Loss, Under Voltage, and Phase Reversal conditions. With normal operating voltages applied in the proper ABC sequence, the internal relay will energize (Pick-Up). When incorrect phase sequence or phase loss occurs or the three-phase voltages fall below the drop out voltages, the relay will de-energize (Drop-Out). On models featuring indicators, the LED glows when all line conditions are normal. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are NOT required. For UL Listed units, with field wiring terminals, copper wire with 60°/75° C rating must be used for control circuitry connections. NOTE: When a phase is lost while the motor is running, a condition known as regeneration occurs where a voltage is induced into the open phase nearly equal in magnitude to the normal phase-to-phase voltage. However, with the exception of lightly loaded motors, enough change is detected by the SLA to provide the required protection when properly adjusted. The SLA Series is UL Listed under File Number E55826.

Product Features

Delta or Wye Systems

Fixed, Lock Shaft, or Screwdriver Adjustment

Available up to 480 VAC (625 VAC with "E" Style)

Several Enclosure Styles