Delivery & Return:Free shipping on all orders over $50
Estimated Delivery:7-15 days international
People:24 people viewing this product right now!
Easy Returns:Enjoy hassle-free returns within 30 days!
Payment:Secure checkout
SKU:29279515
Fault description: The machine suddenly shut down by itself, rebooting only lasts a second or two, or it can not turn on. Solution: If the TF memory card is full, please replace it with a new card in time. Otherwise, there may be a sudden automatic shutdown of the machine, and can not open the machine. If the above problems occur, try the following steps to rectify the fault: 1. Take out the TF memory card on the bottom of the machine 2. After power off, connect the charger to charge for more than 6 hours and then turn it on without the TF memory card to see if it can work. 6-channel Particle Number High precision laser particle sensor User can view 6-channel particle count 0.3 0.5 1.0 2.5 5.0 10 and PM1.0 reading by switching the Curve Button (mode switch button) PM0.3PM0.5PM1.0PM2.5PM5.0PM10 NDIR CO2 optical measurementFull scale Temp. correctionAbsorption gas chamber optical coating72-hour Automatic baseline calibration The percentage of constant constituents in the air is almost constant within 100km from the ground. In terms of volume content, oxygen accounts for approximately 20.95%, nitrogen accounts for approximately 78.09%, and CO2 is approximately 0.03%. The carbon dioxide concentration in the atmospheric environment is very stable, with a value of about 400ppm, even in a clean environment. Data record and data export TF memory card memory card that storage 100K+ data records Data storage frequency: once a minuteConnect the computer via Card ReaderData records can be exported in TXT fileYou can use Excle to open TXT files to analyze data trends Air Quality Assessment AQI Alarm Air quality alarm threshold base on US standard: PM2.5: 0-12μg/m³ GoodPM10: 0-54μg/m³ GoodCO2: 400-700ppm GoodTVOC: 0-5.0mg/m³ GoodHCHO: 0-0.1mg/m³ Good 3-way circular air convection Active air interaction systemincreases contact area with the sensormute fan with low noise Quality design 2.4-inch TFT liquid crystal displayEnergy absorption seismic designData curve trend 128s 126s Add to Cart Add to Cart Customer Reviews 3.9 out of 5 stars 57 3.9 out of 5 stars 25 Price $199.99$199.99 $169.99$169.99 PM1.0 ✓ ✓ PM2.5 ✓ ✓ PM10 ✓ ✓ TVOC ✓ ✓ HCHO ✓ ✓ CO2 ✓ no data Particle Counter 0.3 0.5 1.0 2.5 5.0 10 ✓ ✓ Data record & Data Export ✓ ✓ Precautions for Use Regarding machine reading is high on first use Reason: Because the packaging material itself contains interference gas, and it is sealed in the box for a long time, the charge attached to the surface of the sensor will increase, causing the value of the machine to be biased when it is turned on. Solution: After receiving the machine, put it in an outdoor clean and ventilated environment for about 8 hours, so that the charge can be released. (Charger can be connected to ensure the power supply) Regarding the high TVOC level Please check your measuring point if there are some human activities such as cooking, smoking, drinking or some chemical gases such as perfume, air freshener, detergent, etc. Then try to put the machine in an outdoor clean and ventilated environment for more than 3 hours to see if the machine value will drop. About CO2 sensor calibration The CO2 sensor adopts 72-hour automatic baseline calibration. Plug in the charger, turn on the machine, click the test button, and let the machine run continuously for more than 72 hours. About TVOC and HCHO calibration We should calibrate the equipment in fresh outdoor air, because particulate pollution and chemical pollution are two different types of pollution. Very low particulate matter does not mean that chemical pollution and interfering gases do not exist. To verify whether the machine sensor is normal, please pick up the machine to the mouth, blow hard into the air inlet of the machine, see if the value changes. Precautions for Use Regarding machine reading is high on first use Reason: Because the packaging material itself contains interference gas, and it is sealed in the box for a long time, the charge attached to the surface of the sensor will increase, causing the value of the machine to be biased when it is turned on. Solution: After receiving the machine, put it in an outdoor clean and ventilated environment for about 8 hours, so that the charge can be released. (Charger can be connected to ensure the power supply) Regarding the high TVOC level Please check your measuring point if there are some human activities such as cooking, smoking, drinking or some chemical gases such as perfume, air freshener, detergent, etc. Then try to put the machine in an outdoor clean and ventilated environment for more than 3 hours to see if the machine value will drop. About CO2 sensor calibration The CO2 sensor adopts 72-hour automatic baseline calibration. Plug in the charger, turn on the machine, click the test button, and let the machine run continuously for more than 72 hours. About TVOC and HCHO calibration We should calibrate the equipment in fresh outdoor air, because particulate pollution and chemical pollution are two different types of pollution. Very low particulate matter does not mean that chemical pollution and interfering gases do not exist. To verify whether the machine sensor is normal, please pick up the machine to the mouth, blow hard into the air inlet of the machine, see if the value changes. Test purifying effect of purifier: light a cigarette in a room, place our machine in this room, wait for the readings to go up, and then place the machine next to the hePA filter in another room to see if the high readings go down. Put our machine directly next to the purifier and the reading might not change much. Because there is no change in the air concentration in a normal environment, and when you turn on the purifier, it is impossible to make the reading of air quality monitor become very low. To ensure accurate readings, please test more than 20 minutes: After the machine is turned on, click the yellow test button and the machine will start reading. When the machine is just started to run, the value is constantly changing, because it takes a process for the value to rise from 0. After the machine runs for about 20 minutes and the reading tends to be stable. When we test the air quality in a room, in order to ensure accurate results, we should keep the machine away from some interference factors, such as some perfume, incense, freshener, detergent and other interference gases, as well as smoking, cooking, drinking, human breathing and other human interference factors. Test purifying effect of purifier: light a cigarette in a room, place our machine in this room, wait for the readings to go up, and then place the machine next to the hePA filter in another room to see if the high readings go down. Put our machine directly next to the purifier and the reading might not change much. Because there is no change in the air concentration in a normal environment, and when you turn on the purifier, it is impossible to make the reading of air quality monitor become very low. To ensure accurate readings, please test more than 20 minutes: After the machine is turned on, click the yellow test button and the machine will start reading. When the machine is just started to run, the value is constantly changing, because it takes a process for the value to rise from 0. After the machine runs for about 20 minutes and the reading tends to be stable. When we test the air quality in a room, in order to ensure accurate results, we should keep the machine away from some interference factors, such as some perfume, incense, freshener, detergent and other interference gases, as well as smoking, cooking, drinking, human breathing and other human interference factors.
FINE PARTICLE DUST LEVEL -- Laser air quality sensor can measure indoor dust level in real time. 6-channel tiny particle number detection (Number of particles/liter)--PM0.3, PM0.5, PM1.0, PM2.5, PM5.0, PM10; 3-channel particulate matters quality detection (μg/m³)--PM1.0, PM2.5, PM10
CO2 SENSOR & HCHO SENSOR -- NDIR Non-Spectral Infrared CO2 Carbon Dioxide Sensor with self-calibration, Absorption chamber Optical Coating; Electrochemical formaldehyde HCHO sensor with automatic calibration, double platinum catalytic electrode, strong anti-interference ability
TVOC CHEMICAL POLLUTION -- Semiconductor TVOC VOCmeter can test a variety of volatile organic compounds TVOC VOC, such as benzene, toluene, xylene, aromatic hydrocarbons, aldehydes, hydrogen sulfide etc., captures the change in molecular concentration of organic compounds at the thousandth level
DATA LOGGING UPGTADE -- Portable handheld Smart air quality monitor indoor Support data storage and export of all 12 testing items, with date and time, frequency once every 1 minute. MAX storage capacity can be expanded to 8G, which can store up to 400 days of records
PROFESSIONAL & ORIGINAL-- air quality alarm base on US standard; 2200 mAh rechargeable lithium battery; stereo air convection sampling and active air interactive system; Silent fan without noise; Anti-fall PE soft shell